Dumont Angled Tweezers

or

Dumont Angled Tweezers are superb quality tweezers, ideal for creating beautiful fluffy fans if you are using the "wiggle" technique only. Made in Switzerland, the Dumont Brand, is known all over the world for their high quality, durability and detailed engineering. Dumont handcrafts tools for beauty, jewelry making, medical and many more industries.

Dumont Angled Tweezers are very light, comfortable to use, have a good grip.

 

Note:

Dumont Angled Tweezers are hand-finished therefore each one of them is unique. If you purchase more than one, you might need to adjust to each one. Each pair of tweezers is hand tested by Loreta before they are shipped.

 

Please be aware that because of various techniques and personal habits, even tested, these tweezers might not work for you.

 

Read more about Dumont on our Blog. 

Key info
  • Product information: Dumont 5/45 Inox 08
  • Weight: 20g
  • Length: 12cm

Care & Handling

 RINSING
Immediately after surgery, rinse instruments under warm running water to remove all blood, body fluids and
tissue. If not cleaned immediately after rinsing, instruments should be submerged in a solution of water and
neutral pH (7) detergent until they can be cleaned.
CLEANING
A. Ultrasonic Cleaning
Place instruments in open position into the ultrasonic cleaner. Make sure that instruments with sharp blades
(scissors, etc.) do not touch other instruments. All instruments must be fully submerged.
Do not place dissimilar metals (stainless, copper, chrome plated, etc.) in the same cleaning cycle.
Instruments should be processed in the cleaner for 5 to 10 minutes.
After ultrasonic cleaning, rinse instruments with water to remove ultrasonic cleaning solution.
B. Automatic Washer Sterilizers
Follow manufacturer’s recommendations. Be sure to lubricate instruments after last rinse cycle and before
sterilization cycle.
C. Manual cleaning
Ultrasonic cleaning is the most effective way to clean surgical instruments, especially those with
hinges, locks and moving parts. If ultrasonic cleaning is not available, follow these steps:
I. Use stiff plastic cleaning brushes. Do not use steel wool or wire brushes.
II. Use only neutral pH (7) detergents. (Low pH detergents, if not rinsed off properly, will cause breakdown
of stainless protective surface and black staining. High pH detergents will cause surface deposit of brown
stain, which will also interfere with smooth operation of the instrument.)
III. Brush delicate instruments carefully and, if possible, handle them separately from general instruments.
IV. Make sure all instrument surfaces are visibly clean and free from stains and tissue.
Inspect each instrument for proper function and condition. Make sure that scissor blades glide smoothly
all the way (blades must not be loose when in closed position). Check that forceps tips are properly
aligned. Make sure that hemostats and needle holders do not show light between the jaws, that they lock
and unlock easily, and that the joints are not too loose. Check needle holder jaws for wear. Examine
cutting instruments and knives to be sure their blades are sharp and undamaged.

V. After scrubbing, rinse instruments thoroughly under running water. While rinsing, open and close
scissors, hemostats, needle holders and other hinged instruments to ensure that hinge areas are also
rinsed out.
AUTOCLAVING
A. Lubricate all instruments which have any metal-to-metal action such as scissors, hemostats, needle holders,
self retaining retractors, etc. Surgical instrument lubricants should be used.
Do not use WD-40 oil or other industrial lubricants.
B. Instruments may be autoclaved individually or in sets.
Individual instrumen—tsDisposable paper or plastic pouches are ideal. Make sure you use a wide enough
pouch (4” or wider) for instruments with ratchet locks (such as needles holders and hemostats) so the
instrument can be sterilized in an open (unlocked) position.
Instrument Set—s Unlock all instruments and sterilize them in an open position. Place heavy instruments on
bottom of set (when two layers are required).
Never lock an instrument during autoclaving. This will prevent the steam from reaching and sterilizing the
metal-to-metal surfaces. Furthermore, heart expansion during autoclaving can cause cracks in hinge areas.
Do not overload the autoclave chamber, as this may also hinder steam penetration.
Place a towel on bottom of pan to absorb excess moisture during autoclaving.
Make sure the towels contain no detergent residue and are neutral pH(7) when immersed in water.
(Laundries frequently use inexpensive but high pH(9-13) detergents and do not properly rinse out or
neutralize those detergents in the final wash/rinse cycle. Also, sometimes bleaches are added and are not
neutralized.)
CAUTION— At the end of the autoclave cycle (before the drying cycle) unlock autoclave door and
open it no more than a crack (about 3/4”). Then run dry cycle for the period recommended by the
autoclave manufacturer. If the autoclave door is opened fully before the drying cycle, cold room air will
rush into the chamber, causing condensation on the instruments. This will result in water stains on
instruments and also cause wet packs.
COLD STERILIZATION
Most cold sterilization solutions require a 10-hour immersion to render instruments sterile, but this prolonged
chemical action may be more detrimental to surgical instruments than the 20-minute autoclave cycle. If the
instruments need only to be disinfected (basically clean), cold sterilization is acceptable since disinfection will
take place in only 10 minutes.
But to render the instruments sterile (with absolutely no living organism surviving), autoclaving is
recommended.
For instruments with tungsten carbide inserts (needle holders, scissors, tissue forceps), do not use solutions
containing benzyl ammonium chloride which will destroy the tungsten carbide inserts.
AFTER CLEANING
If instruments are to be stored, let them air dry and store them in a clean and dry environment.

About us

Based on her years of experience as a Master Lash Artist as well as being a leading trainer, a renowned judge and lecturer, Loreta collates and creates a full range of high quality tools and accessories to support eyelash technicians in their career. 

 

Her emphasis is on creating products that will enable her followers to create ‘flawless masterpieces’ and provide the best care to maintain the healthy lashes of their clients.

 

The wide range of Flawless Lashes products are of the highest quality to meet Loreta’s precise standards. 

  • Shipping
  • Reviews
1. Royal Mail Tracked 24 
  • 1–2 day parcel delivery with online tracking
  • Optional signature on delivery
  • SMS and/or email notifications
2. Royal Mail Tracked 48 
  • 2–3 day parcel delivery with online tracking
  • Optional signature on delivery
  • SMS and/or email notifications
3. Royal Mail Special Delivery Guaranteed
  • Delivery by 1pm next working day if ordered by 3pm day before
  • Online tracking
  • Signature on delivery 
  • SMS and/or email notifications
4. Free UK Shipping on Orders Over £60.00
  • 2–3 day parcel delivery with online tracking
  • Optional signature on delivery
  • SMS and/or email notifications
5. Collect from Crawley shop
  • Order Online and choose 'Collect from Crawley shop' at the checkout
  • A charge of £5 will be taken which we will refund on collection
  • Collect from shop between 10am - 4pm, Monday to Friday
  • Bring your order confirmation email with you
  • You will have 48 hours to collect your goods
  • If not collected in time, order will be cancelled and refunded
6. Deutsche Post International Tracking Services
  • Aims to deliver within 5-15 working days
7. International courier Services
  • 2-5 day delivery service anywhere in the world
  • SMS and/or email notifications

Customer Reviews

Based on 2 reviews Write a review



Related Items